InstanceBase.prvPrevInst (PROP) ¶ PROPERTY prvPrevInst : IInstance
InstanceData (FB) ¶ FUNCTION_BLOCK InstanceData IMPLEMENTS IData InOut: Scope Name Type Input hInst CAA.HANDLE Methods: prvCheckDataInst Structure: prvCheckDataInst (Method)
InstanceData.prvCheckDataInst (METH) ¶ METHOD prvCheckDataInst : BOOL InOut: Scope Name Type Return prvCheckDataInst BOOL Output pData POINTER TO InstanceData
Interfaces ¶ IData (Interface) Private prvCheckDataInst (Method) IFactory (Interface) Private prvAllocInstMem (Method) prvFreeInstMem (Method) prvGetInstPointer (Method) prvInsertInst (Method) prvInstCount (Property) prvInstInit (Method) prvInstPoolAdr (Property) prvInstPoolExtendsFactor (Property) prvInstPoolSize (Property) prvInstSize (Property) prvRemoveInst (Method) IInstance (Interface) Dispose (Method) Private prvInstFactory (Property) prvInstInit (Method) prvInstRelease (Method) prvInstRetain (Method) prvNextInst (Property) prvPrevInst (Property)
IData (ITF) ¶ INTERFACE IData EXTENDS __System.IQueryInterface Methods: prvCheckDataInst Structure: Private prvCheckDataInst (Method)
Private ¶ prvCheckDataInst (Method)
IData.prvCheckDataInst (METH) ¶ METHOD prvCheckDataInst : BOOL InOut: Scope Name Type Return prvCheckDataInst BOOL Output pData POINTER TO InstanceData
GetSpecificDeviceError (FB) ¶ FUNCTION_BLOCK GetSpecificDeviceError EXTENDS CBM.ETrigA This function block delivers the fieldbus specific device error. Note The interpretation of pData is fieldbus dependent and will be specified by the associated fieldbus driver. Note This feature may not be supported by all fieldbus drivers. eError will return ERROR.NOT_SUPPORTED if not supported. InOut: Scope Name Type Comment Input itfNode INode device node pData CAA.PVOID Pointer to memory where specific device error information should be copied to. Inout szSize CAA.SIZE IN: Size of memory pData points to. Out: Size of data copied to pData Output eError ERROR operation error code
Reconfigure ¶ A reconfiguration can be used to apply new configuration values to a device and all subdevices. After reconfiguring all changed configuration values (Enable flag, Parameter changes, …) take effect. Reconfigure (FunctionBlock)
Reconfigure (FB) ¶ FUNCTION_BLOCK Reconfigure EXTENDS CBM.ETrig This function block reads and applies the whole configuration of the corresponding device and all subdevices. After Reconfiguring all changed configuration values (Enable flag, Parameter changes, …) take effect. If device doesn’t support reconfiguring eError returns ERROR.NOT_SUPPORTED . Example Following example code disables a slave device beneath a fieldbus master. PROGRAM PLC_PRG VAR iState : INT := 0 ; reconfig : DED.Reconfigure ; END_VAR CASE iState OF 0 : //Disable slave device: Slave1 (= name in device tree) Slave1.Enable := FALSE ; iState := 1 ; 1 : //start reconfiguring of fieldbus master reconfig ( xExecute := TRUE , itfNode := Master ); IF reconfig.xDone THEN iState := 3 ; ELSE IF reconfig.xError THEN iState := 2 ; END_IF 2 : //reconfiguring error //TODO: Add code here reconfig ( xExecute := FALSE ); 3 : //reconfiguring successful ==> slave disabled //TODO: Add code here reconfig ( xExecute := FALSE ); END_CASE Note This feature may not be supported by all fieldbus drivers. eError will return ERROR.NOT_SUPPORTED if not supported. InOut: Scope Name Type Comment Input itfNode INode The node to be reconfigured. Output eError ERROR operation error code