SOFTING_T_FMB_FM2_EVENT_IND (STRUCT) ¶ TYPE SOFTING_T_FMB_FM2_EVENT_IND : STRUCT InOut: Name Type reason UINT
SOFTING_T_FMB_SET_CONFIGURATION_REQ (STRUCT) ¶ TYPE SOFTING_T_FMB_SET_CONFIGURATION_REQ : STRUCT InOut: Name Type Comment fms_active USINT FMS AND FM7 services are usable dp_active USINT DP services are usable fdlif_active USINT FDLIF services are usable sm7_active USINT SM7 services are usable fdl_evt_receiver UINT receiver of FDL events: FMB_USR,FM7_USR,DP_USR,FDLIF_USR data_buffer_length UINT max. size of PDU buffer vfd SOFTING_T_FMB_CONFIG_VFD VFD configuration parameters crl SOFTING_T_FMB_CONFIG_CRL CRL configuration parameters dp SOFTING_T_FMB_CONFIG_DP DP configuration parameter fdlif SOFTING_T_FMB_CONFIG_FDLIF FDLIF configuration parameter sm7 SOFTING_T_FMB_CONFIG_SM7 SM7 configuration parameters
Profibus DP ¶ SOFTING_T_DP_AAT_DATA (Struct) SOFTING_T_DP_BUS_PARA_SET (Struct) SOFTING_T_DP_CFG_DATA (Struct) SOFTING_T_DP_PRM_DATA (Struct) SOFTING_T_DP_SLAVE_PARA_SET (Struct) SOFTING_T_DP_SLAVE_USER_DATA (Struct)
SOFTING_T_DP_AAT_DATA (STRUCT) ¶ TYPE SOFTING_T_DP_AAT_DATA : STRUCT InOut: Name Type aat_data_len UINT number_inputs USINT number_outputs USINT offset_input_output ARRAY [0..243] OF WORD
SOFTING_T_DP_BUS_PARA_SET (STRUCT) ¶ TYPE SOFTING_T_DP_BUS_PARA_SET : STRUCT InOut: Name Type Comment bus_para_len UINT 66..2^16-1 fdl_add USINT 0..125 baud_rate USINT DP_xBAUD_xxx tsl UINT see DIN 19245-1 FOR details min_tsdr UINT max_tsdr UINT tqui USINT tset USINT ttr UINT g USINT hsa USINT max_retry_limit USINT bp_flag USINT DP_BP_ERROR_ACTION min_slave_interval UINT 1..2^16-1 [100 micros] poll_timeout UINT 1..2^16-1 [1 ms] data_control_time UINT 1..2^16-1 [10 ms] reserved ARRAY [0..5] OF USINT master_user_data_len UINT 34..2^16-33 master_class2_name STRING(31) DP Master (CLASS 2) vendor name
SOFTING_T_DP_CFG_DATA (STRUCT) ¶ TYPE SOFTING_T_DP_CFG_DATA : STRUCT InOut: Name Type cfg_data_len UINT cfg_data ARRAY [0..254] OF BYTE
SOFTING_T_DP_PRM_DATA (STRUCT) ¶ TYPE SOFTING_T_DP_PRM_DATA : STRUCT InOut: Name Type prm_data_len UINT station_status USINT wd_fact_1 USINT wd_fact_2 USINT min_tsdr USINT ident_number UINT group_ident USINT user_prm_data ARRAY [0..241] OF BYTE
SOFTING_T_DP_SLAVE_PARA_SET (STRUCT) ¶ TYPE SOFTING_T_DP_SLAVE_PARA_SET : STRUCT InOut: Name Type slave_para_len UINT sl_flag USINT slave_type USINT reserved ARRAY [0..11] OF USINT
SOFTING_T_DP_SLAVE_USER_DATA (STRUCT) ¶ TYPE SOFTING_T_DP_SLAVE_USER_DATA : STRUCT InOut: Name Type slave_user_data_len UINT slave_user_data ARRAY [0..99] OF BYTE
SettgEndUpdate (FUN) ¶ FUNCTION SettgEndUpdate : RTS_IEC_RESULT Function to initiate writing settings to database file, if settings are modified after SettgBeginUpdate was called. NOTE: - Funcion can be called nested, so only at the last call of SettgEndUpdate , the database is written! - Always call SettgBeginUpdate and SettgEndUpdate symmetric!!! InOut: Scope Name Type Comment Return SettgEndUpdate RTS_IEC_RESULT Runtime system error code (see CmpErrors.library).