BACnetIntegerValue.Units (PROP) ¶ PROPERTY Units : CmpBACnet.IEC_BACNET_ENGINEERING_UNITS
BACnetLargeAnalogValue.COVIncrement (PROP) ¶ PROPERTY COVIncrement : CmpBACnet.IEC_BACNET_DOUBLE
BACnetLargeAnalogValue.Deadband (PROP) ¶ PROPERTY Deadband : CmpBACnet.IEC_BACNET_DOUBLE
BACnetIntegerValue.StatusFlags (PROP) ¶ PROPERTY StatusFlags : STRING
BACnetIntegerValue.TimeDelay (PROP) ¶ PROPERTY TimeDelay : CmpBACnet.IEC_BACNET_UNSIGNED
BACNetClientGetEnrollmentSummary.SampleInputs (METH) ¶ METHOD PROTECTED SampleInputs
BACnetClientAcknowledgeAlarm (FB) ¶ FUNCTION_BLOCK PUBLIC FINAL BACnetClientAcknowledgeAlarm EXTENDS BACnetClientBase Common Behaviour Model conform (ETrigA) FB to execute a Acknowledge-Alarm-Reqeust in the BACnet-Network. If the execution completed successfully, xDone is set to TRUE. InOut: Scope Name Type Initial Comment Inherited from Input xExecute BOOL Rising edge: Starts defined operation FALSE : Resets the defined operation after ready condition was reached ETrigATo xAbort BOOL TRUE : Aborts the operation ETrigATo udiTimeOut UDINT Max. operating time for executing [µs], 0: No operating time limit ETrigATo Output xDone BOOL TRUE : Ready condition reached ETrigATo xBusy BOOL TRUE : Operation is running ETrigATo xError BOOL TRUE : Error condition reached ETrigATo xAborted BOOL TRUE : Abort condition reached ETrigATo Input dwTargetDeviceNumber DWORD The device number of the targeted device in the BACnet- Network. BACnetClientBase pTargetDeviceAddress POINTER TO CmpBACnet.IEC_BACNET_ADDRESS 0 Optional : The device address of the targeted device in the BACnet-Network. If an adress is given the given device number is ignored. BACnetClientBase Output eStatus CmpBACnet.IEC_BACNET_STATUS CmpBACnet.IEC_BACNET_STATUS.BACNET_STATUS_OK If an error occured, the error state. BACnetClientBase errorResult CmpBACnet.IEC_BACNET_ERROR STRUCT(tag := CmpBACnet.IEC_BACNET_FAILURE_TYPE._FAILURE_MAX_SIZE) If an error occured (this means eStatus <> BACNET_STATUS_OK), whereas the sent BACnet-Request was answered with an specific error information, the latter is contained in this structure. BACnetClientBase iState DINT 0 The State in which the FB is during execution: 0: No execution, resetted state 1: Searching for the Target-Device and a valid address for it 2: Sending the BACnet-Request into the network 3: Waiting for the answer (if there is one) to the BACnet-Request made in 2 4: Finishing the call, setting of the output variables BACnetClientBase Input processID CmpBACnet.IEC_BACNET_UNSIGNED The ID of the process to acknowledge the alarms with. eventObjInst CmpBACnet.IEC_BACNET_DWORD The object instance to acknowledge the alarms for. eventObjType CmpBACnet.IEC_BACNET_OBJECT_TYPE The object type to acknowledge the alarms for. eventState CmpBACnet.IEC_BACNET_EVENT_STATE Event state to be acknowledged. timeStamp CmpBACnet.IEC_BACNET_TIME_STAMP Time Stamp of the acknowledgement. ackSource WSTRING(255) Identifier of the source of acknowledgement. ackTime CmpBACnet.IEC_BACNET_TIME_STAMP CHECK: BACN-200 Time of the acknowledgemnent. Properties: Instance , inherited from BACnetClientBase Running , inherited from BACnetClientBase Server , inherited from BACnetClientBase SourceDeviceAddress , inherited from BACnetClientBase SourceDeviceNumber , inherited from BACnetClientBase TargetDeviceAddress , inherited from BACnetClientBase TargetDeviceNumber , inherited from BACnetClientBase Methods: Request SampleInputs InitializeOutputs , inherited from BACnetClientBase RegisterToServer , inherited from BACnetClientBase UnregisterFromServer , inherited from BACnetClientBase Structure: Request (Method) SampleInputs (Method)
BACnetClientGetEventInfo (FB) ¶ FUNCTION_BLOCK PUBLIC FINAL BACnetClientGetEventInfo EXTENDS BACnetClientBase Common Behaviour Model conform (ETrigA) FB to execute a Get-Enrollment-Summary-Reqeust in the BACnet-Network. If execution completed successfully, xDone is set to TRUE. InOut: Scope Name Type Initial Comment Inherited from Input xExecute BOOL Rising edge: Starts defined operation FALSE : Resets the defined operation after ready condition was reached ETrigATo xAbort BOOL TRUE : Aborts the operation ETrigATo udiTimeOut UDINT Max. operating time for executing [µs], 0: No operating time limit ETrigATo Output xDone BOOL TRUE : Ready condition reached ETrigATo xBusy BOOL TRUE : Operation is running ETrigATo xError BOOL TRUE : Error condition reached ETrigATo xAborted BOOL TRUE : Abort condition reached ETrigATo Input dwTargetDeviceNumber DWORD The device number of the targeted device in the BACnet- Network. BACnetClientBase pTargetDeviceAddress POINTER TO CmpBACnet.IEC_BACNET_ADDRESS 0 Optional : The device address of the targeted device in the BACnet-Network. If an adress is given the given device number is ignored. BACnetClientBase Output eStatus CmpBACnet.IEC_BACNET_STATUS CmpBACnet.IEC_BACNET_STATUS.BACNET_STATUS_OK If an error occured, the error state. BACnetClientBase errorResult CmpBACnet.IEC_BACNET_ERROR STRUCT(tag := CmpBACnet.IEC_BACNET_FAILURE_TYPE._FAILURE_MAX_SIZE) If an error occured (this means eStatus <> BACNET_STATUS_OK), whereas the sent BACnet-Request was answered with an specific error information, the latter is contained in this structure. BACnetClientBase iState DINT 0 The State in which the FB is during execution: 0: No execution, resetted state 1: Searching for the Target-Device and a valid address for it 2: Sending the BACnet-Request into the network 3: Waiting for the answer (if there is one) to the BACnet-Request made in 2 4: Finishing the call, setting of the output variables BACnetClientBase Input xLastReceivedPresent BOOL Determines whether the following lastReceivedType and lastReceivedInst parameters shall be used. lastReceivedType CmpBACnet.IEC_BACNET_OBJECT_TYPE Type of the last object type received by the GetEventInfo call. lastReceivedInst CmpBACnet.IEC_BACNET_DWORD Type of the last object instance received by the GetEventInfo call. Output result CmpBACnet.IEC_BACNET_EVENT_INFO If the BACnet-Request succeeded (xDone is TRUE and no error occured (xError is FALSE)), this variable holds the contents of the event info. Properties: Instance , inherited from BACnetClientBase Running , inherited from BACnetClientBase Server , inherited from BACnetClientBase SourceDeviceAddress , inherited from BACnetClientBase SourceDeviceNumber , inherited from BACnetClientBase TargetDeviceAddress , inherited from BACnetClientBase TargetDeviceNumber , inherited from BACnetClientBase Methods: FreeResult HasResult InitializeOutputs Request SampleInputs RegisterToServer , inherited from BACnetClientBase UnregisterFromServer , inherited from BACnetClientBase Structure: FreeResult (Method) HasResult (Method) InitializeOutputs (Method) Request (Method) SampleInputs (Method)
BACnetClientGetEventInfo.FreeResult (METH) ¶ METHOD PROTECTED FreeResult
BACnetClientGetAlarmSummary (FB) ¶ FUNCTION_BLOCK PUBLIC FINAL BACnetClientGetAlarmSummary EXTENDS BACnetClientBase Common Behaviour Model conform (ETrigA) FB to execute a Get-Alarm-Summary-Reqeust in the BACnet-Network. If execution completed successfully, xDone is set to TRUE. InOut: Scope Name Type Initial Comment Inherited from Input xExecute BOOL Rising edge: Starts defined operation FALSE : Resets the defined operation after ready condition was reached ETrigATo xAbort BOOL TRUE : Aborts the operation ETrigATo udiTimeOut UDINT Max. operating time for executing [µs], 0: No operating time limit ETrigATo Output xDone BOOL TRUE : Ready condition reached ETrigATo xBusy BOOL TRUE : Operation is running ETrigATo xError BOOL TRUE : Error condition reached ETrigATo xAborted BOOL TRUE : Abort condition reached ETrigATo Input dwTargetDeviceNumber DWORD The device number of the targeted device in the BACnet- Network. BACnetClientBase pTargetDeviceAddress POINTER TO CmpBACnet.IEC_BACNET_ADDRESS 0 Optional : The device address of the targeted device in the BACnet-Network. If an adress is given the given device number is ignored. BACnetClientBase Output eStatus CmpBACnet.IEC_BACNET_STATUS CmpBACnet.IEC_BACNET_STATUS.BACNET_STATUS_OK If an error occured, the error state. BACnetClientBase errorResult CmpBACnet.IEC_BACNET_ERROR STRUCT(tag := CmpBACnet.IEC_BACNET_FAILURE_TYPE._FAILURE_MAX_SIZE) If an error occured (this means eStatus <> BACNET_STATUS_OK), whereas the sent BACnet-Request was answered with an specific error information, the latter is contained in this structure. BACnetClientBase iState DINT 0 The State in which the FB is during execution: 0: No execution, resetted state 1: Searching for the Target-Device and a valid address for it 2: Sending the BACnet-Request into the network 3: Waiting for the answer (if there is one) to the BACnet-Request made in 2 4: Finishing the call, setting of the output variables BACnetClientBase result CmpBACnet.IEC_BACNET_ALARM_INFO If the BACnet-Request succeeded (xDone is TRUE and no error occured (xError is FALSE)), this variable holds the contents of the alarm summary. Properties: Instance , inherited from BACnetClientBase Running , inherited from BACnetClientBase Server , inherited from BACnetClientBase SourceDeviceAddress , inherited from BACnetClientBase SourceDeviceNumber , inherited from BACnetClientBase TargetDeviceAddress , inherited from BACnetClientBase TargetDeviceNumber , inherited from BACnetClientBase Methods: FreeResult HasResult InitializeOutputs Request SampleInputs RegisterToServer , inherited from BACnetClientBase UnregisterFromServer , inherited from BACnetClientBase Structure: FreeResult (Method) HasResult (Method) InitializeOutputs (Method) Request (Method) SampleInputs (Method)