ICmpIoDrvProfibus ¶ ClearData (Method) Freeze (Method) Sync (Method) UnSync (Method) Unfreeze (Method)
IoDrvHilscherProfibusWrapper.ClearData (METH) ¶ METHOD ClearData : UDINT InOut: Scope Name Type Return ClearData UDINT Input udiRemAdr UDINT udiGroupSelect UDINT
IoDrvHilscherProfibusWrapper.Freeze (METH) ¶ METHOD Freeze : UDINT InOut: Scope Name Type Return Freeze UDINT Input udiRemAdr UDINT udiGroupSelect UDINT
IoDrvHilscherProfibusWrapper.Sync (METH) ¶ METHOD Sync : UDINT InOut: Scope Name Type Return Sync UDINT Input udiRemAdr UDINT udiGroupSelect UDINT
IoDrvHilscherProfibusWrapper.UnSync (METH) ¶ METHOD UnSync : UDINT InOut: Scope Name Type Return UnSync UDINT Input udiRemAdr UDINT udiGroupSelect UDINT
IoDrvHilscherProfibusWrapper.Unfreeze (METH) ¶ METHOD Unfreeze : UDINT InOut: Scope Name Type Return Unfreeze UDINT Input udiRemAdr UDINT udiGroupSelect UDINT
IsLibReleased (FUN) ¶ FUNCTION IsLibReleased : BOOL This function has been automatically generated from the project information. InOut: Scope Name Type Return IsLibReleased BOOL
ModbusTCPDeviceDiag (FB) ¶ FUNCTION_BLOCK ModbusTCPDeviceDiag EXTENDS CAADiagDeviceDefault This fucntion block is generated for the Modbus TCP slave device in the device tree if generic DIagnosis is activated. InOut: Scope Name Type Initial Comment Input xEnable BOOL TRUE TRUE : start operation, open sockets Output xOnline BOOL TCP Port opened, ready for receiving request. xInternalError BOOL FALSE Unrecoverable internal error (e.g. if mem-alloc fails or no license) ErrorCode UDINT error code Port UINT Port Number uiClientConnections UINT number of currently established client connections (TCP/IP) xTimeout BOOL Timeout (if configured) expired. Holding Registers and Coils are set to zero. Methods: UpdateCommunicationSettings Structure: UpdateCommunicationSettings (Method)
ModbusTCPDeviceDiag.UpdateCommunicationSettings (METH) ¶ METHOD UpdateCommunicationSettings : DINT Change the TCP-Port number. Existing TCP Connection will be aborted InOut: Scope Name Type Initial Comment Return UpdateCommunicationSettings DINT Input uiPortNr UINT 502 TCP-Port Number used by Modbus Server
File and Project Information ¶ Scope Name Type Content FileHeader creationDateTime date 16.05.2023, 15:44:12 companyName string 3S-Smart Software Solutions GmbH libraryFile IoDrvModbusTCPSlave.library primaryProject True productName CODESYS productProfile CODESYS V3.5 SP16 Patch 3 contentFile IoDrvModbusTCPSlave.clean.json version version 2.0.0.0 ProjectInformation Released bool True LastModificationDateTime date 16.05.2023, 15:44:12 LibraryCategories library-category-list Intern|IoDrivers Author string 3S - Smart Software Solutions GmbH Company 3S - Smart Software Solutions GmbH CompiledLibraryCompatibilityVersion CODESYS V3.5 SP16 DefaultNamespace IoDrvModbusTCPSlaveLibrary Description See: Description DocFormat reStructuredText Placeholder IoDrvModbusTCPSlave Project IoDrvModbusTCPSlave ServerBuildException ok Title IoDrvModbusTCPSlave Version version 4.3.0.0