ISOLayer_FB.TCPIP_Open (ACT) ¶ Waiting for Connections
ISOLayer_FB.TCPIP_Send (ACT) ¶ Senden, wenn Daten in der Que stehen
TOOLS ¶ IEC61850_ReadDWord (Function) IEC61850_ReadISOHeader (Function) IEC61850_ReadString (Function) IEC61850_ReadWord (Function) IEC61850_SetISOEntry (Function) IEC61850_SetISOLen (Function) ISO8327_ReadHeader (Function)
IEC61850_CDC_MV (FB) ¶ FUNCTION_BLOCK IEC61850_CDC_MV InOut: Scope Name Type Comment Inout tyMMS_DataExchange tyIEC61850_MMS_DataExchange Input x_MX BOOL Measurement instMag tyIEC61850_AT_AnalogueValue mag tyIEC61850_AT_AnalogueValue range tyIEC61850_AT_ENUMERATED q tyIEC61850_AT_Quality t tyIEC61850_AT_TimeStamp x_SV BOOL Optionale Eigenschaften (substitution) subEna BOOL subMag tyIEC61850_AT_AnalogueValue subQ tyIEC61850_AT_Quality subID_REF INT x_CF BOOL Optionale Eigenschaften (configuration, description and extension) units tyIEC61850_AT_UNIT db tyIEC61850_AT_UINT32 zeroDb tyIEC61850_AT_UINT32 sVC tyIEC61850_AT_SCALEDVALCONFIG rangeC tyIEC61850_AT_RANGECONFIG smpRate tyIEC61850_AT_UINT32 x_DC BOOL d_REF INT Optionale Referenz auf das String Array in der globalen Liste dU_REF INT Optionale Referenz auf das String Array in der globalen Liste x_Ex BOOL cdcNs_REF INT Optionale Referenz auf das String Array in der globalen Liste cdcName_REF INT Optionale Referenz auf das String Array in der globalen Liste dataNs_REF INT Optionale Referenz auf das String Array in der globalen Liste
IEC61850_CDC_SAV (FB) ¶ FUNCTION_BLOCK IEC61850_CDC_SAV InOut: Scope Name Type Comment Inout tyMMS_DataExchange tyIEC61850_MMS_DataExchange Input x_MX BOOL Measurement instMag tyIEC61850_AT_AnalogueValue q tyIEC61850_AT_Quality t tyIEC61850_AT_TimeStamp x_CF BOOL Configuration units tyIEC61850_AT_UNIT sVC tyIEC61850_AT_SCALEDVALCONFIG min_ tyIEC61850_AT_AnalogueValue max_ tyIEC61850_AT_AnalogueValue x_DC BOOL Description d_REF INT Optionale Referenz auf das String Array in der globalen Liste dU_REF INT Optionale Referenz auf das String Array in der globalen Liste x_Ex BOOL Extension cdcNs_REF INT Optionale Referenz auf das String Array in der globalen Liste cdcName_REF INT Optionale Referenz auf das String Array in der globalen Liste dataNs_REF INT Optionale Referenz auf das String Array in der globalen Liste
IEC61850_CDC_SEQ (FB) ¶ FUNCTION_BLOCK IEC61850_CDC_SEQ InOut: Scope Name Type Initial Comment Inout tyMMS_DataExchange tyIEC61850_MMS_DataExchange Input x_c1 BOOL Measurement x_c2 BOOL x_c3 BOOL c1 IEC61850_CDC_CMV STRUCT(x_SV := FALSE, x_CF := FALSE, x_DC := FALSE, x_EX := FALSE) c2 IEC61850_CDC_CMV STRUCT(x_SV := FALSE, x_CF := FALSE, x_DC := FALSE, x_EX := FALSE) c3 IEC61850_CDC_CMV STRUCT(x_SV := FALSE, x_CF := FALSE, x_DC := FALSE, x_EX := FALSE) x_MX BOOL seqT tyIEC61850_AT_ENUMERATED x_CF BOOL Configuration phsRef tyIEC61850_AT_ENUMERATED x_DC BOOL Description d_REF INT Optionale Referenz auf das String Array in der globalen Liste dU_REF INT Optionale Referenz auf das String Array in der globalen Liste x_Ex BOOL Extionsion cdcNs_REF INT Optionale Referenz auf das String Array in der globalen Liste cdcName_REF INT Optionale Referenz auf das String Array in der globalen Liste dataNs_REF INT Optionale Referenz auf das String Array in der globalen Liste
IEC61850_CDC_WYE (FB) ¶ FUNCTION_BLOCK IEC61850_CDC_WYE InOut: Scope Name Type Initial Comment Inout tyMMS_DataExchange tyIEC61850_MMS_DataExchange Input x_phsA BOOL Measurement x_phsB BOOL x_phsC BOOL x_neut BOOL x_net BOOL x_res BOOL phsA IEC61850_CDC_CMV STRUCT(x_SV := FALSE, x_CF := FALSE, x_DC := FALSE, x_EX := FALSE) phsB IEC61850_CDC_CMV STRUCT(x_SV := FALSE, x_CF := FALSE, x_DC := FALSE, x_EX := FALSE) phsC IEC61850_CDC_CMV STRUCT(x_SV := FALSE, x_CF := FALSE, x_DC := FALSE, x_EX := FALSE) neut IEC61850_CDC_CMV STRUCT(x_SV := FALSE, x_CF := FALSE, x_DC := FALSE, x_EX := FALSE) net IEC61850_CDC_CMV STRUCT(x_SV := FALSE, x_CF := FALSE, x_DC := FALSE, x_EX := FALSE) res IEC61850_CDC_CMV STRUCT(x_SV := FALSE, x_CF := FALSE, x_DC := FALSE, x_EX := FALSE) x_CF BOOL Configuration angRef tyIEC61850_AT_ENUMERATED x_DC BOOL Description d_REF INT Optionale Referenz auf das String Array in der globalen Liste dU_REF INT Optionale Referenz auf das String Array in der globalen Liste x_Ex BOOL Extension cdcNs_REF INT Optionale Referenz auf das String Array in der globalen Liste cdcName_REF INT Optionale Referenz auf das String Array in der globalen Liste dataNs_REF INT Optionale Referenz auf das String Array in der globalen Liste
IEC61850_CDC_ACD (FB) ¶ FUNCTION_BLOCK IEC61850_CDC_ACD InOut: Scope Name Type Comment Inout tyMMS_DataExchange tyIEC61850_MMS_DataExchange Input x_ST BOOL Status general BOOL M dirGeneral tyIEC61850_AT_ENUMERATED phsA BOOL dirPhsA tyIEC61850_AT_ENUMERATED phsB BOOL dirPhsB tyIEC61850_AT_ENUMERATED phsC BOOL dirPhsC tyIEC61850_AT_ENUMERATED neut BOOL dirNeut tyIEC61850_AT_ENUMERATED q tyIEC61850_AT_Quality M t tyIEC61850_AT_TimeStamp M x_DC BOOL Optionale Eigenschaften (configuration, description and extension) d_REF INT Optionale Referenz auf das String Array in der globalen Liste dU_REF INT Optionale Referenz auf das String Array in der globalen Liste x_Ex BOOL cdcNs_REF INT Optionale Referenz auf das String Array in der globalen Liste cdcName_REF INT Optionale Referenz auf das String Array in der globalen Liste dataNs_REF INT Optionale Referenz auf das String Array in der globalen Liste
IEC61850_CDC_ACT (FB) ¶ FUNCTION_BLOCK IEC61850_CDC_ACT InOut: Scope Name Type Comment Inout tyMMS_DataExchange tyIEC61850_MMS_DataExchange Input x_ST BOOL Status general BOOL M phsA BOOL phsB BOOL phsC BOOL Neut BOOL q tyIEC61850_AT_Quality M t tyIEC61850_AT_TimeStamp M operTmPhsA tyIEC61850_AT_TimeStamp M operTmPhsB tyIEC61850_AT_TimeStamp M operTmPhsC tyIEC61850_AT_TimeStamp M x_CF BOOL Optionale Eigenschaften (configuration, description and extension) operTm tyIEC61850_AT_TimeStamp x_DC BOOL d_REF INT Optionale Referenz auf das String Array in der globalen Liste dU_REF INT Optionale Referenz auf das String Array in der globalen Liste x_Ex BOOL cdcNs_REF INT Optionale Referenz auf das String Array in der globalen Liste cdcName_REF INT Optionale Referenz auf das String Array in der globalen Liste dataNs_REF INT Optionale Referenz auf das String Array in der globalen Liste
IEC61850_Init_DataPoints (FUN) ¶ FUNCTION IEC61850_Init_DataPoints : BOOL InOut: Scope Name Type Comment Return IEC61850_Init_DataPoints BOOL Input eName IEC61850_ENUM_ATTR_NAMES Name des Datenpunktes eDataType IEC61850_ENUM_MMS_DataType Datentyp pData POINTER TO BYTE Zeiger auf den Datenpunkt wSizeOf WORD Sizeof des Datenpunkts. Es kann vorkommen, dass die Länge 1 ist, der Datenpunkt aber 4 Byte groß wDataLen WORD Länge der Daten. Bei Bitstring die Anzahl Bits eFC IEC61850_ENUM_FC FC des Datenpunktes eElementTyp IEC61850_ENUM_ELEMENTTYP Element: Element, Sub, Main xCanValueSet BOOL Kann der Wert beschrieben werden eTrgOp IEC61850_ENUM_TRGOPT Trigger Options: 0=IEC61850_TRGOPT_NONE, 1=IEC61850_TRGOPT_DCHG 2=IEC61850_TRGOPT_DUPD, 4=IEC61850_TRGOPT_QCHG Inout nIx INT DataPoint tyIEC61850_DataPoint